{"created":"2023-05-15T08:44:02.489257+00:00","id":9254,"links":{},"metadata":{"_buckets":{"deposit":"9fd71a06-0ab3-47d9-a66e-2321fc2991c9"},"_deposit":{"created_by":13,"id":"9254","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"9254"},"status":"published"},"_oai":{"id":"oai:uec.repo.nii.ac.jp:00009254","sets":["6"]},"author_link":["25321","25320","25323","25319","25322"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-12-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"25","bibliographicPageEnd":"31738","bibliographicPageStart":"31730","bibliographicVolumeNumber":"25","bibliographic_titles":[{},{"bibliographic_title":"Optics Express","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In this study, we demonstrated an improvement in the detection sensitivity of dual-comb spectroscopy using the repetition rate multiplication of optical frequency combs. We compared the dual-comb signals in three dual-comb setups consisting of combinations of two combs with and without mode-filtering, and investigated how the repetition rate influences the signal-to-noise ratio (SNR) of dual-comb measurements. The dual-comb setups using high-repetition-rate combs enabled the absorption lines of HCN gas to be measured with a high SNR in a short averaging time, and real-time spectral data acquisition was realized using a low-sensitivity and low-resolution RF spectrum analyzer.","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Optical Society of America "}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1364/OE.25.031730","subitem_relation_type_select":"DOI"}}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1364/OE.25.031730","subitem_relation_type_select":"DOI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2017 Optical Society of America under the terms of the OSA Open Access Publishing Agreement"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1094-4087","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nishiyama, Akiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"25319","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshida, Satoru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"25320","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hariki, Takuya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"25321","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakajima, Yoshiaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"25322","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Minoshima, Kaoru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"25323","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-06-05"}],"displaytype":"detail","filename":"oe-25-25-31730.pdf","filesize":[{"value":"1.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"oe-25-25-31730","url":"https://uec.repo.nii.ac.jp/record/9254/files/oe-25-25-31730.pdf"},"version_id":"7d8e258b-0ee1-468b-af8f-cf15da518750"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"13","path":["6"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-06-05"},"publish_date":"2019-06-05","publish_status":"0","recid":"9254","relation_version_is_last":true,"title":["Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-05-15T10:20:13.304176+00:00"}