{"created":"2023-05-15T08:43:28.023214+00:00","id":8435,"links":{},"metadata":{"_buckets":{"deposit":"3b15eed4-9063-4f91-bdc4-d6f58674066b"},"_deposit":{"created_by":3,"id":"8435","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8435"},"status":"published"},"_oai":{"id":"oai:uec.repo.nii.ac.jp:00008435","sets":["7:65"]},"author_link":["22958","22959","22960"],"control_number":"8435","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-02-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"75","bibliographicPageStart":"66","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"電気通信大学紀要","bibliographic_titleLang":"ja"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To measure the high current value, we introduced 500 Amps-scale AC-current sensors, and evaluated their performance. The Building E-6 is one of the most electric power-consumption buildings in The University of Electro-Communications. We focus on the 4th floor in the Building E-6 to measure power consumption precisely.\nWe checked panelboard view and distribution board in the Building E-6, and arranged 200 A-scale test environment by improving 5 A-scale evaluation equipment. It might be useful for systematic and wide-area power saving in the future.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"電気通信大学"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"落合, 隆夫","creatorNameLang":"ja"},{"creatorName":"オチアイ, タカオ","creatorNameLang":"ja-Kana"},{"creatorName":"OCHIAI, Takao","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"和田, 紀子","creatorNameLang":"ja"},{"creatorName":"ワダ, ノリコ","creatorNameLang":"ja-Kana"},{"creatorName":"WADA, Noriko","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"竹内, 純人","creatorNameLang":"ja"},{"creatorName":"タケウチ, スミト","creatorNameLang":"ja-Kana"},{"creatorName":"TAKEUCHI, Sumito","creatorNameLang":"en"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-02-27"}],"displaytype":"detail","filename":"290106.pdf","filesize":[{"value":"3.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"290106.pdf","url":"https://uec.repo.nii.ac.jp/record/8435/files/290106.pdf"},"version_id":"244a97bd-ea40-42f1-846f-6c2a0dfcb812"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Current Sensor","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electricity Measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Power Saving","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"フロア単位の電力計測を実現するための大型電流計測センサの動作テストおよび導入 ― 東6号館4階を計測対象として ―","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"フロア単位の電力計測を実現するための大型電流計測センサの動作テストおよび導入 ― 東6号館4階を計測対象として ―","subitem_title_language":"ja"},{"subitem_title":"Electric Power Measurement of The Building E-6 by High Current Sensors","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"3","path":["65"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-02-01"},"publish_date":"2017-02-01","publish_status":"0","recid":"8435","relation_version_is_last":true,"title":["フロア単位の電力計測を実現するための大型電流計測センサの動作テストおよび導入 ― 東6号館4階を計測対象として ―"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2024-02-21T05:55:33.920909+00:00"}