WEKO3
アイテム
{"_buckets": {"deposit": "1f3f6c86-63be-4dae-8bb1-61ce7b809ea2"}, "_deposit": {"created_by": 13, "id": "9416", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "9416"}, "status": "published"}, "_oai": {"id": "oai:uec.repo.nii.ac.jp:00009416", "sets": ["6"]}, "author_link": ["25691", "25693", "25692", "25690"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-01-15", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "30", "bibliographicPageStart": "20", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{}, {"bibliographic_title": "OSA Continuum", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We applied an imaging optical system and convolution analysis to a one-shot 3D imaging method with a chirped optical frequency comb to greatly improve the transverse spatial resolution and depth accuracy. We obtained the high contrast spectral interference of a diffusive surface using the designed lens system and developed a simple and robust analysis technique using convolution of an obtained the interference fringe. The developed method was demonstrated to realize submicron-level uncertainty for the depth measurement. When applied to the surface structure of a coin, it demonstrated a transverse spatial resolution of 8.98 lp/mm and depth resolution of 0.35 µm.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Optical Society (OSA)"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1364/OSAC.381540", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1364/OSAC.381540", "subitem_relation_type_select": "DOI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": " \t© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2578-7519", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kato, Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25690", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchida, Megumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25691", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, Yurina", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25692", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Minoshima, Kaoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25693", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-12-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "osac-3-1-20.pdf", "filesize": [{"value": "5.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 5500000.0, "url": {"label": "osac-3-1-20", "url": "https://uec.repo.nii.ac.jp/record/9416/files/osac-3-1-20.pdf"}, "version_id": "798d8811-37a6-477a-b724-bac7ead09289"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "High-resolution 3D imaging method using chirped optical frequency combs based on convolution analysis of the spectral interference fringe", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "High-resolution 3D imaging method using chirped optical frequency combs based on convolution analysis of the spectral interference fringe", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "13", "path": ["6"], "permalink_uri": "https://uec.repo.nii.ac.jp/records/9416", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-12-23"}, "publish_date": "2019-12-23", "publish_status": "0", "recid": "9416", "relation": {}, "relation_version_is_last": true, "title": ["High-resolution 3D imaging method using chirped optical frequency combs based on convolution analysis of the spectral interference fringe"], "weko_shared_id": -1}
High-resolution 3D imaging method using chirped optical frequency combs based on convolution analysis of the spectral interference fringe
https://uec.repo.nii.ac.jp/records/9416
https://uec.repo.nii.ac.jp/records/9416f044cf14-e9d2-430c-a816-a3defbc2fb4d
名前 / ファイル | ライセンス | アクション |
---|---|---|
osac-3-1-20 (5.5 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-12-23 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | High-resolution 3D imaging method using chirped optical frequency combs based on convolution analysis of the spectral interference fringe | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Kato, Takashi
× Kato, Takashi× Uchida, Megumi× Tanaka, Yurina× Minoshima, Kaoru |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We applied an imaging optical system and convolution analysis to a one-shot 3D imaging method with a chirped optical frequency comb to greatly improve the transverse spatial resolution and depth accuracy. We obtained the high contrast spectral interference of a diffusive surface using the designed lens system and developed a simple and robust analysis technique using convolution of an obtained the interference fringe. The developed method was demonstrated to realize submicron-level uncertainty for the depth measurement. When applied to the surface structure of a coin, it demonstrated a transverse spatial resolution of 8.98 lp/mm and depth resolution of 0.35 µm. | |||||
書誌情報 |
en : OSA Continuum 巻 3, 号 1, p. 20-30, 発行日 2020-01-15 |
|||||
出版者 | ||||||
出版者 | The Optical Society (OSA) | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2578-7519 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1364/OSAC.381540 | |||||
権利 | ||||||
権利情報 | © 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1364/OSAC.381540 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |