WEKO3
アイテム
{"_buckets": {"deposit": "9fd71a06-0ab3-47d9-a66e-2321fc2991c9"}, "_deposit": {"created_by": 13, "id": "9254", "owners": [13], "pid": {"revision_id": 0, "type": "depid", "value": "9254"}, "status": "published"}, "_oai": {"id": "oai:uec.repo.nii.ac.jp:00009254", "sets": ["6"]}, "author_link": ["25321", "25320", "25323", "25319", "25322"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-12-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "25", "bibliographicPageEnd": "31738", "bibliographicPageStart": "31730", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{}, {"bibliographic_title": "Optics Express", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In this study, we demonstrated an improvement in the detection sensitivity of dual-comb spectroscopy using the repetition rate multiplication of optical frequency combs. We compared the dual-comb signals in three dual-comb setups consisting of combinations of two combs with and without mode-filtering, and investigated how the repetition rate influences the signal-to-noise ratio (SNR) of dual-comb measurements. The dual-comb setups using high-repetition-rate combs enabled the absorption lines of HCN gas to be measured with a high SNR in a short averaging time, and real-time spectral data acquisition was realized using a low-sensitivity and low-resolution RF spectrum analyzer.", "subitem_description_type": "Abstract"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Optical Society of America "}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1364/OE.25.031730", "subitem_relation_type_select": "DOI"}}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1364/OE.25.031730", "subitem_relation_type_select": "DOI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2017 Optical Society of America under the terms of the OSA Open Access Publishing Agreement"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1094-4087", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nishiyama, Akiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25319", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Satoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25320", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hariki, Takuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25321", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakajima, Yoshiaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25322", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Minoshima, Kaoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "25323", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-06-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "oe-25-25-31730.pdf", "filesize": [{"value": "1.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1900000.0, "url": {"label": "oe-25-25-31730", "url": "https://uec.repo.nii.ac.jp/record/9254/files/oe-25-25-31730.pdf"}, "version_id": "7d8e258b-0ee1-468b-af8f-cf15da518750"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "13", "path": ["6"], "permalink_uri": "https://uec.repo.nii.ac.jp/records/9254", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-06-05"}, "publish_date": "2019-06-05", "publish_status": "0", "recid": "9254", "relation": {}, "relation_version_is_last": true, "title": ["Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique"], "weko_shared_id": -1}
Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique
https://uec.repo.nii.ac.jp/records/9254
https://uec.repo.nii.ac.jp/records/9254fa64764c-1eb5-4556-95ce-4a40321d487c
名前 / ファイル | ライセンス | アクション |
---|---|---|
oe-25-25-31730 (1.9 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-06-05 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Sensitivity improvement of dual-comb spectroscopy using mode-filtering technique | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Nishiyama, Akiko
× Nishiyama, Akiko× Yoshida, Satoru× Hariki, Takuya× Nakajima, Yoshiaki× Minoshima, Kaoru |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this study, we demonstrated an improvement in the detection sensitivity of dual-comb spectroscopy using the repetition rate multiplication of optical frequency combs. We compared the dual-comb signals in three dual-comb setups consisting of combinations of two combs with and without mode-filtering, and investigated how the repetition rate influences the signal-to-noise ratio (SNR) of dual-comb measurements. The dual-comb setups using high-repetition-rate combs enabled the absorption lines of HCN gas to be measured with a high SNR in a short averaging time, and real-time spectral data acquisition was realized using a low-sensitivity and low-resolution RF spectrum analyzer. | |||||
書誌情報 |
en : Optics Express 巻 25, 号 25, p. 31730-31738, 発行日 2017-12-11 |
|||||
出版者 | ||||||
出版者 | Optical Society of America | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1094-4087 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1364/OE.25.031730 | |||||
権利 | ||||||
権利情報 | © 2017 Optical Society of America under the terms of the OSA Open Access Publishing Agreement | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1364/OE.25.031730 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |